Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Bol Med Hosp Infant Mex ; 80(4): 242-246, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37703553

RESUMO

BACKGROUND: Arterial oxygen saturation (SaO2) values are used to make clinical decisions that might change a patient's prognosis, and it has been proposed as the fifth vital sign. This study aimed to determine the variation of SaO2 at different altitudes above sea level (ASL) in healthy Mexican full-term newborns. METHODS: From July 2018 to June 2019, a cross-over study was conducted in six hospitals at different altitudes ASL in Mexico. SaO2 was measured in 4015 newborns after the first 24 h of birth and before leaving the hospital using pulse oximetry. We analyzed three groups: < 250 m ASL (group 1), 1500 m ASL (group 2), and 2250 m ASL (group 3). RESULTS: The mean SaO2 was 97.6 ± 1.8%. For group 1, mean oxygen saturation was 98.2 ± 1.9%; for group 2, 96.7 ± 1.9%, and for group 3, 96.0 ± 2.1%. A statistically significant difference was observed among the groups (p < 0.001), and this difference was higher between groups 1 and 2 (1.5%, p < 0.001). Linear regression analysis showed a decrease in oxygen saturation of 1.01% for every 1000 m ASL. CONCLUSIONS: We demonstrated a statistically significant reduction in SaO2 levels at higher altitudes. This observation can be relevant for clinical decision-making based on pulse oximetry such as critical congenital heart disease screening in Mexico, where more than half of the population lives above 1500 m ASL.


INTRODUCCIÓN: Los valores de SaO2 (saturación de oxígeno) se utilizan para la toma de decisiones clínicas que podrían cambiar el pronóstico del paciente. El objetivo de este estudio fue determinar la variación de la SaO2 en recién nacidos mexicanos a término sanos a diferentes altitudes en México. MÉTODOS: Se llevó a cabo un estudio transversal en seis hospitales situados a diferentes altitudes en México. Se determinó la SaO2 usando oximetría de pulso en 4015 recién nacidos después de las primeras 24 horas de vida, pero antes del egreso del hospital de nacimiento. Se formaron tres grupos para el análisis: grupo 1 con altitud < 250 m sobre el nivel del mar (SNM); grupo 2, altitud de 1500 m SNM y grupo 3, altitud de 2250 m SNM. RESULTADOS: El promedio de la SaO2 fue de 97.6 ± 1.8%. Para el grupo 1, la media fue 98.2 ± 1.9%, para el 2, 96.7 ± 1.9% y para el 3, 96.0 ± 2.1%. Se observó una diferencia estadísticamente significativa entre los grupos (p < 0.001), que fue mayor entre los grupos 1 y 2 (1.5%, p < 0.001). El análisis de regresión lineal mostró una reducción de 1.01% en la SaO2 por cada 1000 m SNM. CONCLUSIONES: Se demostró una disminución estadísticamente significativa de los valores de SaO2 conforme aumenta la altitud. Esto puede ser de particular relevancia en la toma de decisions clínicas basadas en la oximetría de pulso, como el tamiz neonatal cardiaco, sobre todo en México donde mas de la mitad de la población vive a una altitud superior a 1500 m SNM.


Assuntos
Altitude , Saturação de Oxigênio , Recém-Nascido , Humanos , Estudos Cross-Over , México , Oximetria
2.
Horiz. sanitario (en linea) ; 22(2): 271-278, may.-ago. 2023. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1534537

RESUMO

Resumen Objetivo: Determinar la sensibilidad y especificidad de la oximetría de pulso, para detectar cardiopatías congénitas en recién nacidos sanos en alojamiento conjunto. Material y métodos: El estudio es de tipo multicéntrico, prospectivo y transversal, evaluando pacientes del Hospital Regional de Alta Especialidad "Bicentenario 2010" y el Hospital General "Dr. Norberto Treviño Zapata", en ciudad Victoria Tamaulipas, en un periodo que comprendió desde marzo del 2015 a marzo de 2017. Se determinó la oximetría de pulso a recién nacidos sanos antes del egreso hospitalario. Resultados: Se estudiaron 511 recién nacidos. La sensibilidad detectada fue del 88.89 % y una especificidad del 99.80%. Conclusión: Las cardiopatías congénitas en recién nacidos sanos en alojamiento conjunto, se pueden determinar mediante la oximetría de pulso pre y post-ductal.


Abstract Objective: To determine the sensitivity and specificity of pulse oximetry to detect congenital heart disease in healthy newborns in rooming-in. Material and methods: The study is multicenter, prospective and cross-sectional, evaluating patients from the Regional Hospital of High Specialty "Bicentenario 2010" and the General Hospital "Dr. Norberto Treviño Zapata", in the city of Victoria Tamaulipas, in a period from march 2015 to March 2017. Pulse oximetry was determined in healthy newborns before hospital discharge. Results: 511 newborns were studied. The sensitivity detected was 88.89% and a specificity of 99.80%. Conclusion: Congenital heart disease in healthy newborns in rooming-in can be determined by pre- and post-ductal pulse oximetry.

3.
Bol. méd. Hosp. Infant. Méx ; 80(4): 242-246, Jul.-Aug. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1520285

RESUMO

Abstract Background: Arterial oxygen saturation (SaO2) values are used to make clinical decisions that might change a patient's prognosis, and it has been proposed as the fifth vital sign. This study aimed to determine the variation of SaO2 at different altitudes above sea level (ASL) in healthy Mexican full-term newborns. Methods: From July 2018 to June 2019, a cross-over study was conducted in six hospitals at different altitudes ASL in Mexico. SaO2 was measured in 4015 newborns after the first 24 h of birth and before leaving the hospital using pulse oximetry. We analyzed three groups: < 250 m ASL (group 1), 1500 m ASL (group 2), and 2250 m ASL (group 3). Results: The mean SaO2 was 97.6 ± 1.8%. For group 1, mean oxygen saturation was 98.2 ± 1.9%; for group 2, 96.7 ± 1.9%, and for group 3, 96.0 ± 2.1%. A statistically significant difference was observed among the groups (p < 0.001), and this difference was higher between groups 1 and 2 (1.5%, p < 0.001). Linear regression analysis showed a decrease in oxygen saturation of 1.01% for every 1000 m ASL. Conclusions: We demonstrated a statistically significant reduction in SaO2 levels at higher altitudes. This observation can be relevant for clinical decision-making based on pulse oximetry such as critical congenital heart disease screening in Mexico, where more than half of the population lives above 1500 m ASL.


Resumen Introducción: Los valores de SaO2 (saturación de oxígeno) se utilizan para la toma de decisiones clínicas que podrían cambiar el pronóstico del paciente. El objetivo de este estudio fue determinar la variación de la SaO2 en recién nacidos mexicanos a término sanos a diferentes altitudes en México. Métodos: Se llevó a cabo un estudio transversal en seis hospitales situados a diferentes altitudes en México. Se determinó la SaO2 usando oximetría de pulso en 4015 recién nacidos después de las primeras 24 horas de vida, pero antes del egreso del hospital de nacimiento. Se formaron tres grupos para el análisis: grupo 1 con altitud < 250 m sobre el nivel del mar (SNM); grupo 2, altitud de 1500 m SNM y grupo 3, altitud de 2250 m SNM. Resultados: El promedio de la SaO2 fue de 97.6 ± 1.8%. Para el grupo 1, la media fue 98.2 ± 1.9%, para el 2, 96.7 ± 1.9% y para el 3, 96.0 ± 2.1%. Se observó una diferencia estadísticamente significativa entre los grupos (p < 0.001), que fue mayor entre los grupos 1 y 2 (1.5%, p < 0.001). El análisis de regresión lineal mostró una reducción de 1.01% en la SaO2 por cada 1000 m SNM. Conclusiones: Se demostró una disminución estadísticamente significativa de los valores de SaO2 conforme aumenta la altitud. Esto puede ser de particular relevancia en la toma de decisions clínicas basadas en la oximetría de pulso, como el tamiz neonatal cardiaco, sobre todo en México donde mas de la mitad de la población vive a una altitud superior a 1500 m SNM.

4.
Rev. colomb. cardiol ; 28(6): 583-589, nov.-dic. 2021. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1357233

RESUMO

Resumen Objetivo Describir los resultados del tamizaje con oximetría de pulso en el diagnóstico de cardiopatías congénitas críticas en recién nacidos a término y asintomáticos, en una institución de salud de la ciudad de Cúcuta, durante el año 2018. Método: Se llevó a cabo un estudio de tipo descriptivo, de corte transversal, con recolección de información de manera prospectiva, en el cual se tomó oximetría de pulso a 438 recién nacidos a término, asintomáticos, que se encontraban en el quinto piso del Hospital Universitario Erasmo Meoz entre las 18 y las 48 horas de vida. Resultados El tamizaje fue negativo en un 99.1% de los recién nacidos y positivo en el 0.91%; este porcentaje corresponde a cuatro pacientes a quienes se les solicitó valoración por cardiología pediátrica y ecocardiograma transtorácico, de los cuales uno de ellos fue diagnosticado con transposición de grandes arterias y otro con hipertensión pulmonar moderada, y los dos pacientes restantes fueron sanos y dados de alta. Conclusiones La oximetría de pulso como prueba de tamizaje entre las 18 y las 48 horas de vida fue fundamental para diagnosticar una transposición de grandes arterias en un recién nacido asintomático, permitiéndole un tratamiento oportuno para una patología que representa un gran impacto en la morbimortalidad neonatal. Además, permitió el diagnóstico de hipertensión pulmonar en uno de los neonatos.


Abstract Objective To describe the results of pulse oximetry screening in the diagnosis of critical congenital heart diseases in newborns, in a health institution in Cucuta city, during 2018. Method A descriptive, cross-sectional study was conducted, with information collection prospectively, in which pulse oximetry was taken of 438 asymptomatic newborns at term who are on the fifth floor of the Erasmo Meoz University Hospital between 18 and 48 hours of life. Results Screening was negative in 99.1% of newborns and positive in 0.91%, this percentage corresponds to 4 patients who were asked for evaluation by pediatric cardiology and transthoracic echocardiogram; one of them was diagnosed with transposition of the great arteries, other with moderate pulmonary hypertension, the remaining two patients were healthy and discharged. Conclusions Pulse oximetry as a screening test between 18 and 48 hours of life was essential to diagnose a transposition of the great arteries in an asymptomatic newborn, allowing timely treatment for a pathology that represents a great impact on neonatal morbidity and mortality. Additionally, it allowed the diagnosis of pulmonary hypertension in one of the neonates.

5.
Bol. Hosp. Viña del Mar ; 76(4): 119-122, 2020.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1398337

RESUMO

Las fracturas supracondíleas del húmero (FSCH) representan la segunda lesión más frecuente en la infancia. La clasificación de Gartland, de acuerdo con la dirección y magnitud del desplazamiento orienta hacia su tratamiento. Las fracturas grado I solo requieren inmovilización y los grados del II al IV necesitan reducción generalmente cerrada, y fijación con agujas de Kirschner percutáneas. En los grados III y IV las lesiones neuro-vasculares se pueden presentar debido a las relaciones anatómicas de la fractura. La lesión vascular se debe sospechar y tener siempre en cuenta, debido a las secuelas que se pueden presentar de no tomar una conducta adecuada a tiempo. Actualmente existe controversia acerca de cuándo realizar la exploración quirúrgica ante una extremidad bien perfundida, sin pulso radial como resultado de una FSCH. Varios autores han reportado la utilidad de la onda de pulso en la oximetría como predictor de lesión vascular. En este artículo se presenta un caso clínico de FSCH con extremidad sin pulso y lesión de la arteria braquial, su manejo y evolución final.


Supracondylar fractures of the humerus are the second most frequent lesion of infancy. Gartland's classification uses the direction and magnitude of the displacement to determine its treatment. Grade I fractures need only immobilization and grades II to IV need reduction, generally closed, and percutaneous fixation with Kirschner needles. Neurovascular lesions may be present in grades III and IV because of the anatomic relations to the fracture. Vascular injury must always be suspected and taken into consideration because of the sequelae that may occur if not given adequate treatment promptly.There is currently controversy over when to do a surgical exploration in a well-perfused limb with absent radial pulse resulting from a supracondylar humeral fracture. Several authors have reported the usefulness of the waveformof the pulse oximeter in predicting vascular injury. In this article we present a clinical case of supracondylar humeral fracturewithpulseless limb and brachial artery injury, its management, and the outcome.

6.
Med. UIS ; 32(3): 19-25, Sep.-Dec. 2019. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1114973

RESUMO

Resumen La terapia con oxígeno a largo plazo mejoró la supervivencia de los pacientes con enfermedad pulmonar obstructiva crónica. Las medidas propuestas en las guías clínicas para evaluar la indicación y seguimiento de esta terapia son la presión arterial de oxígeno y la saturación arterial de oxígeno. Se ha generalizado el uso de la oximetría de pulso, pero la información para determinar si estas medidas son intercambiables es insuficiente. El objetivo es revisar los fundamentos fisiológicos de las variables relacionadas con la oxigenación y sus formas de medición. En la evaluación del paciente con patología respiratoria, la saturación de pulso es una ayuda clínica valiosa, sin embargo, sus limitaciones no le permiten, en ciertos rangos, reemplazar la valoración directa en sangre arterial (gasometría arterial) de la saturación arterial y la presión arterial de oxígeno, para determinar la indicación de la oxigenoterapia. MÉD.UIS.2019;32(3):19-25


Abstract Long-term oxygen therapy improves the survival of patients with chronic obstructive pulmonary disease. Measures proposed in clinical clinics to evaluate the indication and monitoring of arterial blood pressure therapy and arterial oxygen saturation. The use of pulse oximetry has been widespread, but the information to determine if these measures are interchangeable is insufficient. The objective is to review the physiological foundations of variables related to oxygenation and their forms of measurement. In the assessment of the patient with respiratory pathology, pulse saturation is a valuable clinical aid., however, its limitations do not allow, in certain ranges, to replace direct arterial blood pressure (arterial blood gas) measurement of arterial saturation and arterial oxygen pressure, to determine the indication of oxygen therapy. MÉD.UIS.2019;32(3):19-25


Assuntos
Humanos , Oximetria , Doença Pulmonar Obstrutiva Crônica , Oxigênio , Oxigenoterapia , Patologia , Pacientes , Pressão , Pulso Arterial , Sobrevida , Terapêutica , Pesos e Medidas , Sangue , Gasometria , Pneumologia , Oxigenação , Pressão Arterial , Sobrevivência
7.
Bol. méd. Hosp. Infant. Méx ; 76(6): 287-293, nov.-dic. 2019. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1089146

RESUMO

Resumen Introducción: La detección de cardiopatías congénitas en la etapa neonatal a partir de un soplo cardiaco o cianosis no es efectiva. Las cardiopatías congénitas críticas, como el tronco arterioso común (TAC), causan la mayoría de las muertes neonatales por malformaciones congénitas. El tamizaje por oximetría de pulso en los recién nacidos detecta hasta el 70% de estas cardiopatías. El TAC presenta una alta mortalidad en el primer año de vida. Caso clínico: Se presenta el caso de un paciente de sexo femenino de 4 años de edad con soplo cardiaco, palpitaciones, disnea y cianosis perioral, con diagnóstico al nacimiento de soplo inocente. Se detectó TAC mediante una ecocardiografía. Las resistencias vasculares pulmonares fueron evaluadas por medio de cateterismo cardiaco derecho, con hallazgo de hipertensión arterial pulmonar y vasorreactividad pulmonar. Se realizó corrección quirúrgica. A la fecha, la hipertensión arterial pulmonar continúa presente, por lo que se implementó Bosentan® (Actelion, USA) como tratamiento a largo plazo. Conclusiones: En recién nacidos, el tamizaje por oximetría de pulso después de las 24 horas de vida es un método efectivo para el diagnóstico oportuno de cardiopatías congénitas críticas antes de los signos de colapso cardiovascular. Por ello, resulta una herramienta diagnóstica fundamental para reducir la morbimortalidad. Aunque la corrección quirúrgica de cardiopatías congénitas con hipertensión arterial pulmonar es factible en algunos pacientes, su manejo subsecuente es complejo e impacta de manera adversa en la calidad de vida.


Abstract Background: The detection of congenital heart disease in newborns, based on a heart murmur or cyanosis is not effective. Critical congenital heart diseases, such as truncus arteriosus (TA), cause most of neonatal deaths due to congenital malformations. The screening for pulse oximetry in newborns detects up to 70% of these heart diseases. TA presents high mortality in the first year of life. Case report: A 4-year-old female patient with a heart murmur, palpitations, dyspnea, and perioral cyanosis was diagnosed with an innocent heart murmur at birth. TA was detected by echocardiography. Pulmonary vascular resistances were evaluated through right cardiac catheterization, and pulmonary arterial hypertension and pulmonary vasoreactivity were diagnosed as well. Surgical correction was performed. Currently, pulmonary arterial hypertension persists, for which Bosentan® (Actelion, USA) has been implemented as a long-term treatment. Conclusions: In newborns, the pulse oximetry screening after 24 hours of life is an effective method for suitable diagnosis of critical congenital heart disease before the signs of cardiovascular collapse. Therefore, it has become an essential diagnostic tool to reduce morbidity and mortality. Although the surgical correction of congenital heart disease with pulmonary arterial hypertension is feasible in some patients, its subsequent management is complex and has an adverse impact on the quality of life.


Assuntos
Pré-Escolar , Feminino , Humanos , Sopros Cardíacos/diagnóstico , Hipertensão Arterial Pulmonar/diagnóstico , Cardiopatias Congênitas/diagnóstico , Persistência do Tronco Arterial/cirurgia , Persistência do Tronco Arterial/diagnóstico por imagem , Oximetria , Sopros Cardíacos/congênito , Bosentana/uso terapêutico , Hipertensão Arterial Pulmonar/tratamento farmacológico , Hipertensão Arterial Pulmonar/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Cardiopatias Congênitas/fisiopatologia , Anti-Hipertensivos/uso terapêutico
8.
Bol Med Hosp Infant Mex ; 76(6): 287-293, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31769438

RESUMO

Background: The detection of congenital heart disease in newborns, based on a heart murmur or cyanosis is not effective. Critical congenital heart diseases, such as truncus arteriosus (TA), cause most of neonatal deaths due to congenital malformations. The screening for pulse oximetry in newborns detects up to 70% of these heart diseases. TA presents high mortality in the first year of life. Case report: A 4-year-old female patient with a heart murmur, palpitations, dyspnea, and perioral cyanosis was diagnosed with an innocent heart murmur at birth. TA was detected by echocardiography. Pulmonary vascular resistances were evaluated through right cardiac catheterization, and pulmonary arterial hypertension and pulmonary vasoreactivity were diagnosed as well. Surgical correction was performed. Currently, pulmonary arterial hypertension persists, for which Bosentan® (Actelion, USA) has been implemented as a long-term treatment. Conclusions: In newborns, the pulse oximetry screening after 24 hours of life is an effective method for suitable diagnosis of critical congenital heart disease before the signs of cardiovascular collapse. Therefore, it has become an essential diagnostic tool to reduce morbidity and mortality. Although the surgical correction of congenital heart disease with pulmonary arterial hypertension is feasible in some patients, its subsequent management is complex and has an adverse impact on the quality of life.


Introducción: La detección de cardiopatías congénitas en la etapa neonatal a partir de un soplo cardiaco o cianosis no es efectiva. Las cardiopatías congénitas críticas, como el tronco arterioso común (TAC), causan la mayoría de las muertes neonatales por malformaciones congénitas. El tamizaje por oximetría de pulso en los recién nacidos detecta hasta el 70% de estas cardiopatías. El TAC presenta una alta mortalidad en el primer año de vida. Caso clínico: Se presenta el caso de un paciente de sexo femenino de 4 años de edad con soplo cardiaco, palpitaciones, disnea y cianosis perioral, con diagnóstico al nacimiento de soplo inocente. Se detectó TAC mediante una ecocardiografía. Las resistencias vasculares pulmonares fueron evaluadas por medio de cateterismo cardiaco derecho, con hallazgo de hipertensión arterial pulmonar y vasorreactividad pulmonar. Se realizó corrección quirúrgica. A la fecha, la hipertensión arterial pulmonar continúa presente, por lo que se implementó Bosentan® (Actelion, USA) como tratamiento a largo plazo. Conclusiones: En recién nacidos, el tamizaje por oximetría de pulso después de las 24 horas de vida es un método efectivo para el diagnóstico oportuno de cardiopatías congénitas críticas antes de los signos de colapso cardiovascular. Por ello, resulta una herramienta diagnóstica fundamental para reducir la morbimortalidad. Aunque la corrección quirúrgica de cardiopatías congénitas con hipertensión arterial pulmonar es factible en algunos pacientes, su manejo subsecuente es complejo e impacta de manera adversa en la calidad de vida.


Assuntos
Cardiopatias Congênitas/diagnóstico , Sopros Cardíacos/diagnóstico , Hipertensão Arterial Pulmonar/diagnóstico , Anti-Hipertensivos/uso terapêutico , Bosentana/uso terapêutico , Pré-Escolar , Feminino , Cardiopatias Congênitas/fisiopatologia , Cardiopatias Congênitas/cirurgia , Sopros Cardíacos/congênito , Humanos , Oximetria , Hipertensão Arterial Pulmonar/diagnóstico por imagem , Hipertensão Arterial Pulmonar/tratamento farmacológico , Persistência do Tronco Arterial/diagnóstico por imagem , Persistência do Tronco Arterial/cirurgia
9.
Arch Cardiol Mex ; 89(1): 159-166, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31702739

RESUMO

Introduction and objectives: In some centers, the pulse oximetry is not performed with the justification of lack of the adequate oximeter. We compared the effectiveness of two brands of oximeters to perform it. Methods: In neonates, a term of the joint housing service of the Hospital General de Occidente in Zapopan, Jalisco, Mexico, from May to November 2018, an examination of the characteristics of the American Academy of Pediatrics with both oximeters (ChoiceMMed® and Masimo SET®) was carried out, comparing the detection of critical congenital heart disease, time of intake, and false positives. Results: In each group, 1022 patients were analyzed; with the Masimo SET® oximeter, 83 positive tests were obtained (8.12%), of which 22 cases had some heart disease (26.5%), which represents a sensitivity of 100%, specificity of 93.9%, positive predictive value of 26.5%, and negative predictive value of 100% (odds ratio [OR]: 0.73; 95% confidence interval [CI] 0.6-0.8). With the ChoiceMMed® oximeter, 168 positive tests were obtained (16.4%), of which 22 cases had some heart disease (13.09%), with a sensitivity of 100%, specificity of 85.4%, positive predictive value of 13.09%, and negative predictive value 100% (OR: 0.86; 95%CI: 0.8-0.92). Regarding the time to perform the cardiac sieve, the mean in minutes of the Masimo SET® oximeter was 5.38 and the ChoiceMMed® oximeter was 9.7 min. Conclusions: The ChoiceMMed® oximeter contains a large number of false positives and a greater number of echocardiograms and comparatively longer cardiac screen printing with Masimo SET®, however, both with a negative predictive value of 100% eliminating such excuses.


Introducción y objetivos: En algunos centros el tamiz cardíaco no se realiza con la justificación de no tener el oxímetro adecuado. Comparamos la efectividad de dos marcas de oxímetros para realizarlo. Métodos: En los neonatos a término del Servicio de alojamiento conjunto del Hospital General de Occidente en Zapopan Jalisco México de mayo a noviembre del 2018 se realizó tamiz cardíaco según las guías de la Academia Americana de Pediatría con dos oxímetros, el Masimo SET® (aprobado por la FDA) y el ChoiceMMed®, comparando su efectividad para la detección de cardiopatías congénitas críticas, el tiempo de toma y los falsos positivos. Resultados: En cada grupo se analizaron 1,022 pacientes; con el oxímetro Massimo SET® se obtuvieron 83 pruebas positivas (8.12%) de las cuales 22 casos presentaron alguna cardiopatía (26.5%), lo que representa una sensibilidad del 100%, una especificidad del 93.9%, un valor predictivo positivo del 26.5% y un valor predictivo negativo del 100% (Odd Ratio [OR]: 0.73; IC 95%: 0.6-0.8). Con el oxímetro ChoiceMMed® se obtuvieron 168 pruebas positivas (16.4%), de las cuales 22 casos presentaron alguna cardiopatía (13.09%), con una sensibilidad del 100%, una especificidad del 85.4%, un valor predictivo positivo del 13.09% y un valor predictivo negativo del 100% (OR: 0.86; IC 95%: 0.8-0.92). En cuanto al tiempo para realizar el tamiz cardíaco, la media en minutos del oxímetro Masimo SET® fue 5.38 y del oxímetro ChoiceMMed® fue 9.7 minutos. Conclusiones: El oxímetro ChoiceMMed® presentó mayor cantidad de falsos positivos y mayor tiempo de realización del tamiz cardíaco en comparación al Masimo SET®, sin embargo, ambos presentan un valor predictivo negativo del 100%, siendo igualmente útiles como método de detección de cardiopatías críticas.


Assuntos
Cardiopatias Congênitas/diagnóstico , Cardiopatias/congênito , Cardiopatias/diagnóstico , Oximetria/instrumentação , Algoritmos , Estado Terminal , Desenho de Equipamento , Feminino , Humanos , Recém-Nascido , Estudos Longitudinais , Masculino , Estudos Prospectivos , Sensibilidade e Especificidade
10.
Rev. chil. pediatr ; 90(4): 384-391, ago. 2019. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1020646

RESUMO

INTRODUCCIÓN: El oxímetro de pulso ha sido útil en la evaluación cardiorrespiratoria del neonato. OBJETIVO: Evaluar la saturación arterial de oxígeno (SpO2) y frecuencia cardíaca (FC) en recién nacidos (RN) en los pri meros 60 minutos después del nacimiento. PACIENTES Y MÉTODO: Estudio observacional prospectivo en RN de término sanos, nacidos por vía vaginal o cesárea, con apego materno, efectuado a nivel del mar. Se obtuvo registro continuo de SpO2 post-ductal y de FC desde el minuto 1 al 10 post-natal, y luego a los 15, 30 y 60 minutos. La SpO2 y FC se midieron con un oxímetro de pulso Nellcor. Para el análisis estadístico se utilizó programa Stata v.14. RESULTADOS: Se enrolaron 324 RNT sanos, que cum plieron criterios de inclusión, de los cuales 160 nacieron por vía vaginal y 164 por cesárea. La SpO2 aumentó progresivamente desde el minuto 1 (58,7%) hasta el minuto 10 (94,5%). Los RN por vía vaginal presentaron una SpO2 significativamente mayor hasta el minuto 10 post-natal respecto a los nacidos por cesárea (p < 0,001). En los neonatos nacidos por vía vaginal, la FC fue significativamente mayor en los 2 primeros minutos post-natales, y luego desde el minuto 10 al 60 (p < 0,003). No se encontraron diferencias por género en SpO2 y FC. CONCLUSIÓN: En RNT la SpO2 post-natal aumenta progresivamente, siendo mayor en los primeros 10 minutos en los nacidos por vía vaginal. En los RN por vía vaginal se observó también una FC mayor en los primeros y últimos minutos evaluados.


INTRODUCTION: The pulse oximeter has been useful in the cardiorespiratory evaluation of the newborn. OBJECTIVE: To assess arterial oxygen saturation (SpO2) and heart rate (HR) in newborns in the first 60 minutes after birth. PATIENTS AND METHOD: Prospective observational study in healthy term newborns, delivered vaginally or by cesarean section, with maternal bonding, carried out at sea level. A continuous post ductal SpO2 and HR record were obtained from minute 1 to 10 after birth, and then at 15, 30 and 60 minutes. The SpO2 and HR were measured with a Nellcor pulse oximeter. The software Stata v.14 was used for the statistical analysis. RESULTS: 324 healthy term newborns that met the inclusion criteria were included, of which 160 born vaginally and 164 by cesarean section. The SpO2 increased progres sively from minute 1 (58.7%) to minute 10 (94.5%). Newborns delivered vaginally had a significantly higher SpO2 until minute 10 after birth than those born by cesarean section (p < 0.001). In newborns delivered vaginally, HR was significantly higher in the first two minutes after birth, and then from minute 10 to 60 (p < 0.003). There were no differences by gender in SpO2 and HR. CONCLUSION: In term newborns, the SpO2 increases progressively, being higher in the first 10 minutes in those born vaginally. In newborns delivered vaginally, a higher HR was also observed in the first and last minutes evaluated.


Assuntos
Humanos , Masculino , Feminino , Recém-Nascido , Oxigênio/sangue , Oximetria , Frequência Cardíaca/fisiologia , Fatores de Tempo , Cesárea , Estudos Prospectivos , Parto Obstétrico/métodos
11.
Arch Cardiol Mex ; 89(2): 172-180, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31314010

RESUMO

Introduction and objectives: In some centers the pulse oximetry is not performed with the justification of lack of the adequate oximeter. We compared the effectiveness of two brands of oximeters to perform it. Methods: In neonates a term of the joint housing service of a Hospital General de Occidente in Zapopan Jalisco Mexico from May-November 2018, an examination of the characteristics of the American Academy of Pediatrics with both oximeters (ChoiceMMed® and Masimo SET®) was carried out, comparing the detection of critical congenital heart disease (CCC), time of intake and false positives. Results: In each group 1,022 patients were analyzed; with the Masimo SET® oximeter 83 positive tests were obtained (8.12%), of which 22 cases had some heart disease (26.5%), which represents a sensitivity of 100%, specificity of 93.9%, positive predictive value of 26.5% and negative predictive value of 100% (OR: 0.73; 95% CI: 0.6-0.8). With the ChoiceMMed® oximeter, 168 positive tests were obtained (16.4%), of which 22 cases had some heart disease (13.09%), with a sensitivity of 100%, specificity of 85.4%, positive predictive value of 13.09% and negative predictive value 100% (OR: 0.86; 95% CI: 0.8-0.92). Regarding the time to perform the cardiac sieve, the mean in minutes of the Masimo SET® oximeter was 5.38 and the ChoiceMMed® oximeter was 9.7 minutes. Conclusions: The ChoiceMMed® oximeter contains a large number of false positives and a greater number of echocardiograms and comparatively longer cardiac screen printing with Masimo SET®, however, both with a negative predictive value of 100% eliminating such excuses.


Introducción y objetivos: En algunos centros el tamiz cardíaco no se realiza con la justificación de no tener el oxímetro adecuado. Comparamos la efectividad de dos marcas de oxímetros para realizarlo. Métodos: En los neonatos a término del Servicio de alojamiento conjunto del Hospital General de Occidente en Zapopan Jalisco México de mayo a noviembre del 2018 se realizó tamiz cardíaco según las guías de la Academia Americana de Pediatría con dos oxímetros, el Masimo SET® (aprobado por la FDA) y el ChoiceMMed®, comparando su efectividad para la detección de cardiopatías congénitas críticas, el tiempo de toma y los falsos positivos. Resultados: En cada grupo se analizaron 1,022 pacientes; con el oxímetro Massimo SET® se obtuvieron 83 pruebas positivas (8.12%) de las cuales 22 casos presentaron alguna cardiopatía (26.5%), lo que representa una sensibilidad del 100%, una especificidad del 93.9%, un valor predictivo positivo del 26.5% y un valor predictivo negativo del 100% (Odd Ratio [OR]: 0.73; IC 95%: 0.6-0.8). Con el oxímetro ChoiceMMed® se obtuvieron 168 pruebas positivas (16.4%), de las cuales 22 casos presentaron alguna cardiopatía (13.09%), con una sensibilidad del 100%, una especificidad del 85.4%, un valor predictivo positivo del 13.09% y un valor predictivo negativo del 100% (OR: 0.86; IC 95%: 0.8-0.92). En cuanto al tiempo para realizar el tamiz cardíaco, la media en minutos del oxímetro Masimo SET® fue 5.38 y del oxímetro ChoiceMMed® fue 9.7 minutos. Conclusiones: El oxímetro ChoiceMMed® presentó mayor cantidad de falsos positivos y mayor tiempo de realización del tamiz cardíaco en comparación al Masimo SET®, sin embargo, ambos presentan un valor predictivo negativo del 100%, siendo igualmente útiles como método de detección de cardiopatías críticas.

12.
Arch. cardiol. Méx ; 89(2): 172-180, Apr.-Jun. 2019. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1142179

RESUMO

Resumen Introducción y objetivos: En algunos centros el tamiz cardíaco no se realiza con la justificación de no tener el oxímetro adecuado. Comparamos la efectividad de dos marcas de oxímetros para realizarlo. Métodos: En los neonatos a término del Servicio de alojamiento conjunto del Hospital General de Occidente en Zapopan Jalisco México de mayo a noviembre del 2018 se realizó tamiz cardíaco según las guías de la Academia Americana de Pediatría con dos oxímetros, el Masimo SET (aprobado por la FDA) y el ChoiceMMed, comparando su efectividad para la detección de cardiopatías congénitas críticas, el tiempo de toma y los falsos positivos. Resultados: En cada grupo se analizaron 1,022 pacientes; con el oxímetro Massimo SET se obtuvieron 83 pruebas positivas (8.12%) de las cuales 22 casos presentaron alguna cardiopatía (26.5%), lo que representa una sensibilidad del 100%, una especificidad del 93.9%, un valor predictivo positivo del 26.5% y un valor predictivo negativo del 100% (Odd Ratio [OR]: 0.73; IC 95%: 0.6-0.8). Con el oxímetro ChoiceMMed se obtuvieron 168 pruebas positivas (16.4%), de las cuales 22 casos presentaron alguna cardiopatía (13.09%), con una sensibilidad del 100%, una especificidad del 85.4%, un valor predictivo positivo del 13.09% y un valor predictivo negativo del 100% (OR: 0.86; IC 95%: 0.8-0.92). En cuanto al tiempo para realizar el tamiz cardíaco, la media en minutos del oxímetro Masimo SET fue 5.38 y del oxímetro ChoiceMMed fue 9.7 minutos. Conclusiones: El oxímetro ChoiceMMed presentó mayor cantidad de falsos positivos y mayor tiempo de realización del tamiz cardíaco en comparación al Masimo SET, sin embargo, ambos presentan un valor predictivo negativo del 100%, siendo igualmente útiles como método de detección de cardiopatías críticas.


Abstract Introduction and objectives: In some centers the pulse oximetry is not performed with the justification of lack of the adequate oximeter. We compared the effectiveness of two brands of oximeters to perform it. Methods: In neonates a term of the joint housing service of a Hospital General de Occidente in Zapopan Jalisco Mexico from May-November 2018, an examination of the characteristics of the American Academy of Pediatrics with both oximeters (ChoiceMMed and Masimo SET) was carried out, comparing the detection of critical congenital heart disease (CCC), time of intake and false positives. Results: In each group 1,022 patients were analyzed; with the Masimo SET oximeter 83 positive tests were obtained (8.12%), of which 22 cases had some heart disease (26.5%), which represents a sensitivity of 100%, specificity of 93.9%, positive predictive value of 26.5% and negative predictive value of 100% (OR: 0.73; 95% CI: 0.6-0.8). With the ChoiceMMed oximeter, 168 positive tests were obtained (16.4%), of which 22 cases had some heart disease (13.09%), with a sensitivity of 100%, specificity of 85.4%, positive predictive value of 13.09% and negative predictive value 100% (OR: 0.86; 95% CI: 0.8-0.92). Regarding the time to perform the cardiac sieve, the mean in minutes of the Masimo SET oximeter was 5.38 and the ChoiceMMed oximeter was 9.7 minutes. Conclusions: The ChoiceMMed oximeter contains a large number of false positives and a greater number of echocardiograms and comparatively longer cardiac screen printing with Masimo SET, however, both with a negative predictive value of 100% eliminating such excuses.

13.
Arch. cardiol. Méx ; 88(4): 298-305, oct.-dic. 2018. graf
Artigo em Espanhol | LILACS | ID: biblio-1124151

RESUMO

Resumen Se trata de un estudio de revisión de datos publicados en literatura médica relacionada con el cribado usado para la detección temprana de cardiopatías congénitas complejas en recién nacidos aparentemente sanos en diversas ciudades del mundo, incluyendo los reportados en México, desde aquellos en los que se realiza el cribado por el conocimiento de la fisiopatologìa de datos indirectos de hipoxia, observación de cianosis diferencial y la consecuente diferencia en los valores de la pulsioximetría pre y posductal derivada de la dependencia ductal y/o de comunicación interauricular de diversas cardiopatías congénitas graves, hasta aquellos estudios de investigación realizados de forma masiva y reportados como multicéntricos, justificando la utilidad de la práctica para su implementación cotidiana y obligada de forma extensa a nivel internacional. Asimismo se citan tópicos legislativos en nuestro país como parte de los esfuerzos para establecer la obligatoriedad del cribado en toda la República Mexicana.


Abstract A review is presented of data published in medical literature related to the screening used for the early detection of complex congenital heart disease in apparently healthy newborns in several cities of the world, including those reported in Mexico. The screening wasperformed due to the knowledge of the pathophysiology of indirect hypoxia data, observation of differential cyanosis and the consequent difference in the values of pre- and post-ductal pulse oximetry derived from the ductal and/or atrial septal defect dependence of several severe congenital heart diseases. Multicentre research studies have also been carried out on a massive scale, thus justifying the usefulness of the practice for its daily implementation and at international level. Additionally, legislative topics are cited in our country as part of the efforts to establish the mandatory nature of the screening throughout the Mexican Republic.


Assuntos
Humanos , Recém-Nascido , Oximetria/métodos , Triagem Neonatal/métodos , Cardiopatias Congênitas/diagnóstico , Diagnóstico Precoce , Cardiopatias Congênitas/fisiopatologia , Hipóxia/diagnóstico , México
14.
Neumol. pediátr. (En línea) ; 13(3): 113-117, sept. 2018. graf, ilus, tab
Artigo em Espanhol | LILACS | ID: biblio-947620

RESUMO

Oxygen therapy is frequent in prematures to treat respiratory conditions typically associated with them. Long-term use is mainly due to Bronchopulmonary Dysplasia (BPD). However, the use of oxygen has been controversial in the last decade especially given the associated risk of hyperoxemia in these children. Pulse oximetry (SpO2) is a fundamental tool to guide oxygen therapy. Different trials have found that, in prematures born ≤28 weeks of gestational age who requires oxygen, a restrictive SpO2 target (85-89%) vs a liberal one (91-95%) may cause a higher mortality rate and enterocolitis, but less serious retinopathy. These targets are not normal SpO2 values. Studies on SpO2 reference values in preterm infants are scarce, heterogeneous and they do not necessarily use highly accurate and latest generation pulse oximeters. This contributes to the variation of oxygen therapy among different centers and reinforces the relevance of having SpO2 reference values in preterm infants to safely guide oxygen therapy.


La terapia con oxígeno es frecuente en prematuros para el tratamiento de patología respiratoria propia de su condición. En forma crónica la principal causa de su uso es Displasia Broncopulmonar (DBP). Sin embargo, el uso de oxígeno en prematuros ha sido motivo de debate en la última década fundamentalmente por los riesgos asociados a estados de hiperoxemia. La oximetría de pulso (SpO2) es una herramienta fundamental para guiar la oxigenoterapia. En prematuros que nacen ≤28 semanas de edad gestacional que requieren oxígeno, distintos estudios han demostrado que una meta de SpO2 restrictiva (85-89%) vs liberal (91-95%) tendría mayor mortalidad y enterocolitis, pero menor retinopatía grave. Estas metas no son valores normales de SpO2. Los estudios sobre valores de referencia de SpO2 en prematuros son limitados, heterogéneos y no necesariamente con oxímetros de última generación de mayor precisión. Esto contribuye a que la oxigenoterapia sea variable entre distintos centros y refuerza la relevancia de contar con valores de referencia de SpO2 en prematuros para guiar con seguridad el uso de oxígeno.


Assuntos
Humanos , Recém-Nascido , Oxigenoterapia/métodos , Recém-Nascido Prematuro , Oximetria/normas , Consumo de Oxigênio , Oxigenoterapia/efeitos adversos , Valores de Referência , Monitorização Fisiológica
15.
Arch. argent. pediatr ; 116(3): 429-432, jun. 2018. tab, ilus
Artigo em Espanhol | LILACS, BINACIS | ID: biblio-950020

RESUMO

La cianosis es la coloración azulada de la piel y las mucosas debida al aumento de la concentración de hemoglobina reducida en los capilares o a la presencia de metahemoglobina en concentraciones mayores de las normales. Es importante pensar en metahemoglobinemia como diagnóstico diferencial frente a un paciente con cianosis que no responde a la administración de oxígeno cuando no existen causas cardiorrespiratorias que la justifiquen, dado que requiere de otros métodos diagnósticos y de tratamiento específico. Se presenta el caso de un paciente adolescente de 14 años de edad con cianosis secundaria a metahemoglobinemia de probable etiología congénita. Se discuten las causas, forma de presentación, diagnóstico y tratamiento.


The bluish coloration of skin and mucous membranes, called as cyanosis, could be explained by high reduced hemoglobin in the capillaries, or the presence of elevated methemoglobin concentration. It is important to think of methemoglobinemia as a differential diagnosis in a cyanotic patient who does not respond to oxygen administration once cardiorespiratory causes are discarded; since it requires other diagnostic methods and specific treatment. We described a case of cyanosis in a fourteen-year-old adolescent with probable congenital methemoglobinemia. We discussed their probable causes, clinic presentation, diagnosis and treatment.


Assuntos
Humanos , Masculino , Adolescente , Cianose/etiologia , Metemoglobinemia/congênito , Cianose/diagnóstico , Diagnóstico Diferencial , Metemoglobinemia/complicações , Metemoglobinemia/diagnóstico
16.
Pediátr. Panamá ; 47(1): 13-19, Abril-Mayo 2018.
Artigo em Espanhol | LILACS | ID: biblio-885142

RESUMO

Introducción. Existen evidencias sólidas que demuestran la utilidad de realizar de manera sistemática una prueba de saturación de oxígeno a todos los recién nacidos aparentemente sanos después de 24 horas de nacido y antes de 48 horas; a esta prueba se le ha llamado "tamiz neonatal para cardiopatías congénitas" y sirve para detectar oportunamente anomalías cardiacas estructurales congénitas que cursan con hipoxemia. El tamiz de cardiopatías congénitas puede ayudar a reconocerlas tempranamente y posibilitar su mejor evolución. Objetivos. Evaluar el uso de la oximetría de pulso como herramienta de detección de las cardiopatías congénitas en los recién nacidos asintomáticos. Resultados. Se realizó la prueba de tamizaje cardíaco mediante oximetría de pulso a 2236 recién nacidos sanos asintomáticos, nacidos en el Hospital Materno Infantil José D. de Obaldía (HMIJDDO) en un período de seis meses (agosto 2014-febrero 2015). De esta muestra se obtuvo un tamiz positivo en 16 de los recién nacidos evaluados (0.72%). A los cuales se les realizó ecocardiograma que reportó: 6 casos (37.5%) con un corazón estructuralmente normal, 6 (37.5%) con Ductus Arteriosos Persistentes, 3 (18.75%) Conexiones Anómalas de Venas Pulmonares, y sólo en un caso (6.25%) se presentó un Síndrome de Ventrículo Derecho Hipoplásico, Hipoplasia de Válvula Tricúspide, Atresia pulmonar vs Estenosis Crítica de Válvula en Domo, Conducto Arterioso Grande y Tortuoso, Sospecha de Fístulas Ventrículo-Coronarias. Conclusión. Los padres y los médicos deben saber que una prueba de saturación normal, no descarta la presencia de otras cardiopatías congénitas que no cursan con hipoxemia. Una vez tengamos capacitado un personal que realice este tamizaje, podemos poner la oximetría como control para todos, pero no como un tamiz aislado, sino como un dato más para una fisiopatología que estemos pensando.


Introduction. There is solid evidence that demonstrate the utility of testing in a systematic way of oxygen saturation all the healthy newborn infants apparently after 24 hours old and within 48 hours; This proof has been called "screening neonatal for congenital heart disease" and serves to opportunely detect congenital structural cardiac abnormalities that present with hypoxemia. Sieve of congenital heart disease may help recognize them early and facilitate their better development. Objectives. Evaluate the use of pulse oximetry as a tool for detection of congenital heart diseases in the newborn asymptomatic. Results. The cardiac screening using pulse oximetry test was performed to healthy newborns 2236 asymptomatic, born in the Hospital Materno Infantil José Domingo de Obaldía (HMIJDDO) in a period of six months (August 2014-February 2015). This sample was obtained a positive screen in 16 of the newborns assessed (0.72%). Which was les echo reported: 6 (37.50%) with a structurally normal heart, 6 (37.50%) Arteriosus persistent ductus, 3 (18.75%) Anomalous pulmonary venous connections. And only in one case (6.25%) presented a right hypoplastic ventricle, tricuspid valve, pulmonary Atresia hypoplasia syndrome vs valve stenosis-criticism in dome, large patent ductus arteriosus and tortuous, suspicion of ventricle-coronary fistula. Conclusion. Parents and physicians should know that a normal saturation test, doesn´t rule out the presence of other congenital heart disease who dont present with hypoxemia. Once we have trained staff who perform this screening, we can put the oximetry as a control for all, not as an isolated sieve, but one fact more for a pathophysiology that we are thinking.

17.
Arch Cardiol Mex ; 88(4): 298-305, 2018.
Artigo em Espanhol | MEDLINE | ID: mdl-29548601

RESUMO

A review is presented of data published in medical literature related to the screening used for the early detection of complex congenital heart disease in apparently healthy newborns in several cities of the world, including those reported in Mexico. The screening was performed due to the knowledge of the pathophysiology of indirect hypoxia data, observation of differential cyanosis and the consequent difference in the values of pre- and post-ductal pulse oximetry derived from the ductal and/or atrial septal defect dependence of several severe congenital heart diseases. Multicentre research studies have also been carried out on a massive scale, thus justifying the usefulness of the practice for its daily implementation and at international level. Additionally, legislative topics are cited in our country as part of the efforts to establish the mandatory nature of the screening throughout the Mexican Republic.


Assuntos
Cardiopatias Congênitas/diagnóstico , Triagem Neonatal/métodos , Oximetria/métodos , Diagnóstico Precoce , Cardiopatias Congênitas/fisiopatologia , Humanos , Hipóxia/diagnóstico , Recém-Nascido , México
18.
Rio de Janeiro; s.n; 2017. 99 p. tab, ilus, graf.
Tese em Português | BBO - Odontologia | ID: biblio-946659

RESUMO

O objetivo do presente estudo foi monitorar os sinais vitais em crianças e adolescentes submetidos aos diferentes tratamentos na Odontopediatria. Inicialmente foi realizada uma revisão sistemática da literatura para avaliar se procedimentos odontológicos em crianças são capazes de provocar mudanças na pressão sanguínea. Com relação a revisão sistemática, cinco artigos preencheram os critérios de inclusão, na busca eletrônica nas bases Lilacs, PubMed, Web of Science, e Scopus, e concluiu-se que existe evidencia moderada para suportar as mudanças na pressão sanguínea em crianças submetidas a procedimentos odontológicos. Posteriormente, foi elaborado a pesquisa que gerou o segundo artigo da Tese denominado Aferição das alterações nos sinais vitais em crianças frente aos procedimentos em Odontopediatria e o seu perfil social foi dividido em duas fases. A fase I: clínica e a fase II: questionários. A fase I examinou 64 crianças e adolescentes atendidos na clínica de Odontopediatria da Faculdade de Odontologia da Universidade Federal do Rio de Janeiro divididos em 2 grupos: 32 pacientes compareceram para Revisão (Grupo R) com aferição da pressão arterial (PA), frequência cardíaca e saturação periférica de oxigênio antes e depois do procedimento odontológico. O outro Grupo A, também com 32 pacientes foram submetidos a anestesia para o tratamento, sendo aferido a pressão arterial, frequência cardíaca e oximetria, no início do tratamento, após a anestesia e no final do tratamento. Os responsáveis pelos pacientes dos dois grupos receberam o questionário para obter dados da saúde, hábitos alimentares, atividade física e nível socioeconômico. A frequência cardíaca mostrou diferença significativa (p<0,001) entre o início e o final dos tratamentos nos dois grupos. Houve elevação da pressão sistólica e diastólica em 28,8% dos pacientes do grupo R e em 38,4% dos do Grupo A, tendo retornado ao normal em 96,8% dos pacientes. As alterações de elevação da pressão arterial ocorreram na fase inicial dos procedimentos. Podemos supor que o fator ansiedade e medo iniciais contribuem para esta alteração. Na fase II (questionário) a elevada ingestão de biscoitos (79,7%) e de refrigerantes (84,4%) durante a semana pelos participantes do estudo além da prática de atividade física (37,5%) apenas uma vez por semana, foram achados relevantes e preocupantes nesta pesquisa. O presente estudo demonstrou pequenas alterações nos parâmetros cardíacos avaliados nos dois grupos, sendo que o retorno à normalidade após o final dos procedimentos foi verificado. Uma atenção maior aos hábitos alimentares não saudáveis capazes de produzir alterações cardíacas nas crianças e adolescentes em longo prazo e a falta da prática de atividades físicas regulares devem ser mais bem divulgadas e discutidas nas mídias sociais e nos consultórios odontopediátricos. (AU)


The research underscores the fact that little is known about the influence of cardiac alterations on the child's health and its implications on dental treatment. Primary factors such as, Obesity, sodium concentrations in food, inadequate diet and idleness in the present day, are generating a new lifestyle. The objective of the present study was to monitor the vital signs in children and adolescents submitted to different treatments in Pediatric Dentistry. A systematic review of the literature was carried out to evaluate whether dental procedures in children are capable of causing changes in blood pressure. Regarding the systematic review, five articles met the criteria for inclusion in the electronic search in the databases: Lilacs, PubMed, Web of Science, and Scopus, and concluded that there is moderate evidence to support changes in blood pressure in children undergoing dental procedures. Article 2, titled Measurement of changes in the body in children in relation to procedures in Pediatric Dentistry and its social profile was divided into two phases. Phase I: clinical and phase II: questionnaires. Phase I examined 64 children and adolescents attending the Pediatric Dentistry Clinic of the Faculty of Dentistry of the Federal University of Rio de Janeiro. Subjects were divided into two groups: 32 patients attended for Revision (Group R) for gauging blood pressure, heart rate and peripheral saturation of Oxygen before and after the dental procedure. The other group, A, also with 32 patients underwent anesthesia for the treatment, being measured arterial pressure, heart rate and oximetry, at the beginning of treatment, after anesthesia and at the end of the treatment. Patients in both groups received the questionnaire to obtain health data, eating habits, physical activity and socioeconomic status. The heart rate showed a significant difference (p <0.001) between the beginning and the end of treatments in both groups. There was an increase in systolic and diastolic pressure in 28.8% of patients in-group R and in 38.4% of patients in-group A, and returned to normal in 96.8% of patients. Changes in blood pressure occurred in the initial phase of the procedures. We may assume that the initial anxiety and fear factors contribute to this change. In phase II (questionnaire) the high intake of biscuits (79.7%) and soft drinks (84.4%) during the week by study participants beyond practice of physical activity (37.5%) only once a week were found to be relevant and worrying in this study. The present study showed small changes in the cardiac parameters evaluated in both groups, and the return to normal after the end of the procedures was verified. Greater attention to unhealthy eating habits capable of producing cardiac changes in children and adolescents in the long term and lack of regular physical activity should be better publicized and discussed in social media and pediatric dental care. (AU)


La encuesta pone de relieve la atención sobre el hecho de que se sabe poco acerca de la influencia de los cambios cardíacos en la salud del niño y sus implicaciones para el tratamiento dental. factores primarios tales como la obesidad, las concentraciones de sodio en los alimentos, la dieta poco saludable y la inactividad en estos días, la creación de un nuevo estilo de vida. El propósito de este estudio fue monitorear los signos vitales en niños y adolescentes sometidos a distintos tratamientos en odontología pediátrica. Una revisión sistemática de la literatura se realizó para evaluar si los procedimientos dentales en los niños son capaces de provocar cambios en la presión arterial.. En cuanto a la revisión sistemática cinco artículos cumplieron los criterios de inclusión, la búsqueda electrónica en las bases de datos: lilas, PubMed, Web of Science y Scopus, y resulta que hay evidencia moderada de cambios en la presión arterial en niños sometidos a procedimientos dentales. Posteriormente fue elaborado um segundo artículo medición de los cambios en el cuerpo en frente de los niños en los procedimientos de odontología pediátrica y su perfil social, dividido en dos fases. Fase I: Clinica y fase II cuestionarios. Em La fase de exame clínico fueron examinados 64 niños y adolescentes en atendidos em La clínica de odontología pediátrica de la Faculadad de Odontología de la Universidad Federal de Río de Janeiro.divididos en 2 grupos: 32 pacientes procedían de Revisión (Grupo R) con la presión arterial, la frecuencia cardíaca y la saturación periférica de oxígeno antes y después del procedimiento dental. El otro (grupo A), de 32 pacientes también se sometió a anestesia para el tratamiento, y se mide la presión arteriall, ritmo cardíaco y oximetría de pulso al comienzo del tratamiento, después de la anestesia y el final de tratamento.Os responsable de los pacientes de ambos grupos recibido el cuestionario para los datos de salud, hábitos alimenticios, actividad física y el estatus socioeconómico. La frecuencia cardíaca fue significativamente diferente (p <0,001) entre el inicio y el final del tratamiento en ambos grupos. No hubo aumento en la presión arterial sistólica y diastólica en 28,8% del grupo R y el 38,4% del grupo A, retornando a la normalidad en 96,8% de los pacientes. Los cambios de elevación de la presión arterial se producen en la etapa inicial del procedimiento. Podemos suponer que la ansiedad inicial y factor miedo que contribuye a esta fase alteração. En la fase II (cuestionario) alto consumo de galletas (79,7%) y bebidas no alcohólicas (84,4%) durante la semana por los participantes en el estudio y la práctica actividad física (37,5%) una vez por semana, fueron hallazgos relevantes y preocupantes en esta investigación. El presente estudio demostró pequeños cambios en parámetros cardíacos evaluados en dos grupos, con el retorno a la normalidad después de que el final del procedimiento fueron verificados. Una mayor atención a los malos hábitos alimenticios pueden producir anomalías cardíacas en niños y adolescentes en el largo plazo y la falta de actividad física regular debería estar mejor difusión y debate en los medios de comunicación y consultorios Odontopediatricos. (AU)


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Ansiedade ao Tratamento Odontológico/epidemiologia , Assistência Odontológica para Crianças/efeitos adversos , Frequência Cardíaca , Hipertensão/epidemiologia , Sinais Vitais , Pressão Arterial , Assistência Odontológica para Crianças/psicologia , Oximetria
19.
Rev. Fac. Med. (Guatemala) ; 1(21 Segunda Época): 50-54, jul - dic 2016.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-969505

RESUMO

Introducción: la oximetría de pulso es un método de monitoreo que permite evaluar la saturación arterial y la frecuencia cardíaca y con el cual es posible detectar de forma temprana episodios de hipoxia, bradicardia o taquicardia. Se ha implementado su uso como estrategia para disminuir las tasas de mortalidad. Guatemala recibió la donación de 142 oxímetros de pulso a 33 hospitales departamentales en noviembre del 2013. Objetivos: evaluar el impacto de la oximetría de pulso a través de la medición de la razón de mortalidad materna antes y después de su implementación en el área de recuperación de los hospitales departamentales del país. Métodos: Conocer la mortalidad materna por medio de datos publicados por el Ministerio de Salud de los años 2013 (antes de la implementación) y 2014 (después de la implementación). Resultados: La mortalidad materna disminuyó un 13.26% luego de la implementación de la oximetría de pulso, sin embargo no existe una diferencia significativa. Discusión: No es posible concluir que la causa de la disminución de la mortalidad materna se deba a la implementación de la oximetría pues, otros factores como mejora de calidad de vida, mayor acceso a servicios de salud se ven involucrados


Introduction: Pulse oximetry is a monitoring method that measure a patient´s arterial saturation and heart rate allowing to detect early signs of hypoxia, bradycardia or tachycardia. Its use has been implemented as a strategy to lower mortality rates. Guatemala received the donation of 142 pulse oximeters to 33 regional hospitals on November 2013. Objectives: This study aimed to evaluate the impact of pulse oximetry by measuring maternal mortality ratio before and after its implementation in these hospitals recovery rooms. Methods: Estimation of maternal mortality ratio from data published by the Ministry of Health during the years 2013 (before its implementation) and 2014 (after its implementation). Results: Maternal mortality ratio was 13.26% lower after the implementation of pulse oximetry, however there is no statistical significant difference. Discussion: Is not possible to conclude that the implementation of the pulse oximetry is the only reason in the decrease in maternal mortality since other factors like improvement in quality of life and more access to health services are also involved

20.
Neumol. pediátr. (En línea) ; 11(2): 81-84, abr. 2016. graf, ilus
Artigo em Espanhol | LILACS | ID: biblio-835065

RESUMO

The introduction of pulse oximetry in clinical practice has allowed for simple and non-invasive measurement of arterial oxygen saturation. However, theoretical principles are not always well known and well understood by health care professionals. They must know factors that affect measurements, like motion artifacts poor perfusion being the most important. The calculation of the percentage of arterial oxyhemoglobin is based on the distinct characteristics of light absorption in the red and infrared spectra by oxygenated versus deoxygenated hemoglobin. Now they are new technologies to minimize measuremet errors, thus contributing to an appropriate clinical decision making.


La introducción de la oximetría de pulso en la práctica clínica ha permitido medir en forma sencilla y no invasiva la saturación arterial de oxígeno. Sin embargo, los principios teóricos no siempre son bien conocidos ni bien comprendidos por los profesionales de la salud. Deben conocer los factores que afectan a las mediciones, como artefactos de movimiento y mala perfusión, siendo los más importantes. El cálculo del porcentaje de oxihemoglobina arterial se basa en las características distintivas de absorción de luz en el espectro rojo e infrarrojos por parte de la hemoglobina oxigenada frente a la desoxigenada. Actualmente existen nuevas tecnologías para reducir al mínimo los errores de medición, lo que contribuye a una adecuada toma de decisiones clínicas.


Assuntos
Humanos , Criança , Hipóxia/diagnóstico , Oximetria/instrumentação , Oximetria/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...